Product Detailed
fingertip pulse oximeter 1Dependable Oxygen level and Pulse Rate 2 Low power consumption 3Dual color OLED display

fingertip pulse oximeter

The scope of application

Pulse Oximeter can be detected SPO2 and pulse rate through finger. The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) etc.

Features:

Dependable Oxygen level and Pulse RateSimple operation ,Small & lightweight design, portableLow power consumptionDisplay SpO2, PR, Pulse BarDual color OLED display2 AAA alkaline batteriesLow Battery indicationAuto power on/offAccommodates widest range of finger sizes from pediatric to adultSoft Silicone Padding, Strong Slip Resistant Clip, No Pricking

Technical specification:

Patient rangeAdult, pediatrics

SpO2Measuring range: 35% - 99%Resolution: 1%Accuracy: 70%-99%: ±2%, 35%-69%: unspecified

PRMeasuring range: 30bpm – 250bpmResolution: 1bpmAccuracy:±3%

Display: Type: Dual-color OLED display Parameter: SpO2, PR and Pulse Bar Mode: 1 display mode

Alarm: Battery-low indicator

Battery:2 AAA alkaline batteriesNormal operation time is about 20 hours.

Operation:

Temperature: 5°C~ 40°CHumidity: 15% ~ 90% (non-condensing)Atmospheric pressure: 700hpa ~ 1060hpa

Storage:

Temperature: -20°C ~ 70°CHumidity: 5% ~ 95%Atmospheric pressure: 500hpa ~ 1060hpa

Electromagnetic CompatibilityThe product complies with IEC60601-1-2 for electromagnetic compatibility Class B

Interference Resistance Capacity against Ambient LightDeviation is smaller than ±1% between values of Oxyhemoglobin measured in natural lighting indoor condition and present lighting sources and that measured in dark room